Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters

Database
Language
Document Type
Year range
1.
Int J Environ Res Public Health ; 19(14)2022 07 16.
Article in English | MEDLINE | ID: covidwho-1938802

ABSTRACT

(1) Background: Severe acute respiratory syndrome coronavirus type 2 (SARS-CoV-2) continues to cause profound health, economic, and social problems worldwide. The management and disinfection of materials used daily in health centers and common working environments have prompted concerns about the control of coronavirus disease 2019 (COVID-19) infection risk. Ozone is a powerful oxidizing agent that has been widely used in disinfection processes for decades. The aim of this study was to assess the optimal conditions of ozone treatment for the elimination of heat-inactivated SARS-CoV-2 from office supplies (personal computer monitors, keyboards, and computer mice) and clinical equipment (continuous positive airway pressure tubes and personal protective equipment) that are difficult to clean. (2) Methods: The office supplies and clinical equipment were contaminated in an area of 1 cm2 with 1 × 104 viral units of a heat-inactivated SARS-CoV-2 strain, then treated with ozone using two different ozone devices: a specifically designed ozonation chamber (for low-medium ozone concentrations over large volumes) and a clinical ozone generator (for high ozone concentrations over small volumes). SARS-CoV-2 gene detection was carried out using quantitative real-time polymerase chain reaction (RT-qPCR). (3) Results: At high ozone concentrations over small surfaces, the ozone eliminated SARS-CoV-2 RNA in short time periods-i.e., 10 min (at 4000 ppm) or less. The optimum ozone concentration over large volumes was 90 ppm for 120 min in ambient conditions (24 °C and 60-75% relative humidity). (4) Conclusions: This study showed that the appropriate ozone concentration and exposure time eliminated heat-inactivated SARS-CoV-2 RNA from the surfaces of different widely used clinical and office supplies, decreasing their risk of transmission, and improving their reutilization. Ozone may provide an additional tool to control the spread of the COVID-19 pandemic.


Subject(s)
COVID-19 , Ozone , COVID-19/prevention & control , Humans , Pandemics/prevention & control , RNA, Viral , SARS-CoV-2
2.
Antioxidants (Basel) ; 9(12)2020 Dec 03.
Article in English | MEDLINE | ID: covidwho-962749

ABSTRACT

BACKGROUND: Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is causing profound health, economic, and social problems worldwide. Management of personal protective equipment (PPE) and its potential limited availability have created concerns about the increased risks for healthcare professionals at hospitals and nursing homes. Ozone is a powerful oxidant agent. The objectives of this study were to examine the effects of ozone treatment on PPE contaminated with SARS-CoV-2, and to explore whether relative humidity could modify those effects. METHODS: PPE contaminated by heat-inactivated SARS-CoV-2 were treated with different ozone concentrations, exposure times, and relative humidity conditions. SARS-CoV-2 gene amplification was assessed by real-time polymerase chain reaction. RESULTS: There was no amplification of SARS-CoV-2 in PPE after the following ozone exposures: 30 s at 10,000 ppm (20 g/m3), 5 min at 4000 ppm, and 10 min at 2000 ppm. At lower ozone concentrations, 4-12 ppm (0.008-0.024 g/m3), the effects were highly dependent on the relative humidity conditions. CONCLUSIONS: Oxidative stress induced by ozone exposure eliminated heat-inactivated SARS-CoV-2 in different PPE components under appropriate exposure times, ozone concentrations, and relative humidity conditions. These findings could have implications in decreasing the risk of contamination associated with personal protective equipment management and in increasing its availability. Further research in the original SARS-CoV-2 strain is guaranteed.

SELECTION OF CITATIONS
SEARCH DETAIL